\[ \begin{align}\begin{aligned}\newcommand\blank{~\underline{\hspace{1.2cm}}~}\\% Bold symbols (vectors)
\newcommand\bs[1]{\mathbf{#1}}\\% Differential
\newcommand\dd[2][]{\mathrm{d}^{#1}{#2}} % use as \dd, \dd{x}, or \dd[2]{x}\\% Poor man's siunitx
\newcommand\unit[1]{\mathrm{#1}}
\newcommand\num[1]{#1}
\newcommand\qty[2]{#1~\unit{#2}}\\\newcommand\per{/}
\newcommand\squared{{}^2}
\newcommand\cubed{{}^3}
%
% Scale
\newcommand\milli{\unit{m}}
\newcommand\centi{\unit{c}}
\newcommand\kilo{\unit{k}}
\newcommand\mega{\unit{M}}
%
% Percent
\newcommand\percent{\unit{{\kern-4mu}\%}}
%
% Angle
\newcommand\radian{\unit{rad}}
\newcommand\degree{\unit{{\kern-4mu}^\circ}}
%
% Time
\newcommand\second{\unit{s}}
\newcommand\s{\second}
\newcommand\minute{\unit{min}}
\newcommand\hour{\unit{h}}
%
% Distance
\newcommand\meter{\unit{m}}
\newcommand\m{\meter}
\newcommand\inch{\unit{in}}
\newcommand\foot{\unit{ft}}
%
% Force
\newcommand\newton{\unit{N}}
\newcommand\kip{\unit{kip}} % kilopound in "freedom" units - edit made by Sri
%
% Mass
\newcommand\gram{\unit{g}}
\newcommand\g{\gram}
\newcommand\kilogram{\unit{kg}}
\newcommand\kg{\kilogram}
\newcommand\grain{\unit{grain}}
\newcommand\ounce{\unit{oz}}
%
% Temperature
\newcommand\kelvin{\unit{K}}
\newcommand\K{\kelvin}
\newcommand\celsius{\unit{{}^\circ C}}
\newcommand\C{\celsius}
\newcommand\fahrenheit{\unit{{}^\circ F}}
\newcommand\F{\fahrenheit}
%
% Area
\newcommand\sqft{\unit{sq\,\foot}} % square foot
%
% Volume
\newcommand\liter{\unit{L}}
\newcommand\gallon{\unit{gal}}
%
% Frequency
\newcommand\hertz{\unit{Hz}}
\newcommand\rpm{\unit{rpm}}
%
% Voltage
\newcommand\volt{\unit{V}}
\newcommand\V{\volt}
\newcommand\millivolt{\milli\volt}
\newcommand\mV{\milli\volt}
\newcommand\kilovolt{\kilo\volt}
\newcommand\kV{\kilo\volt}
%
% Current
\newcommand\ampere{\unit{A}}
\newcommand\A{\ampere}
\newcommand\milliampereA{\milli\ampere}
\newcommand\mA{\milli\ampere}
\newcommand\kiloampereA{\kilo\ampere}
\newcommand\kA{\kilo\ampere}
%
% Resistance
\newcommand\ohm{\Omega}
\newcommand\milliohm{\milli\ohm}
\newcommand\kiloohm{\kilo\ohm} % correct SI spelling
\newcommand\kilohm{\kilo\ohm} % "American" spelling used in siunitx
\newcommand\megaohm{\mega\ohm} % correct SI spelling
\newcommand\megohm{\mega\ohm} % "American" spelling used in siunitx
%
% Capacitance
\newcommand\farad{\unit{F}}
\newcommand\F{\farad}
\newcommand\microfarad{\micro\farad}
\newcommand\muF{\micro\farad}
%
% Inductance
\newcommand\henry{\unit{H}}
\newcommand\H{\henry}
\newcommand\millihenry{\milli\henry}
\newcommand\mH{\milli\henry}
%
% Power
\newcommand\watt{\unit{W}}
\newcommand\W{\watt}
\newcommand\milliwatt{\milli\watt}
\newcommand\mW{\milli\watt}
\newcommand\kilowatt{\kilo\watt}
\newcommand\kW{\kilo\watt}
%
% Energy
\newcommand\joule{\unit{J}}
\newcommand\J{\joule}
%
% Composite units
%
% Torque
\newcommand\ozin{\unit{\ounce}\,\unit{in}}
\newcommand\newtonmeter{\unit{\newton\,\meter}}
%
% Pressure
\newcommand\psf{\unit{psf}} % pounds per square foot
\newcommand\pcf{\unit{pcf}} % pounds per cubic foot
\newcommand\pascal{\unit{Pa}}
\newcommand\Pa{\pascal}
\newcommand\ksi{\unit{ksi}} % kilopound per square inch
% NOTE: do NOT define \bar -- it is the built-in LaTeX accent used by \bar{x},
% \bar{y} (sample means). Redefining it made those render as the word "bar".
\newcommand\barunit{\unit{bar}}
\end{aligned}\end{align} \]
Nov 16, 2026 | 399 words | 4 min
read
19.3. GHU-2 Commissioning Report
At a Glance
What this page is: A memo from the client about two CO2 sensor faults found when the
GHU-2 flight unit was commissioned, and the telemetry log from that test. Milestone 4
adds both faults to the acceptance test.
Where you use it: Step 3 of
Milestone 4 - Iteration #2: Greenhouse Controller.
The GHU-2 flight unit completed a six-sol commissioning test before integration. The
unit ran on its flight sensors and actuators under a simple test controller. Our crew
also measured CO2 with a handheld reference analyzer every two hours. The test found two
problems with the CO2 sensors that the mission brief did not anticipate.
The K30 froze twice. Our reference samples confirm both events. The frozen readings
did not look like the GHU-1 freezes in the telemetry your team analyzed in
Milestone 2.
The SCD41 was wrong for hours at a time. Our reference samples disagreed with it by
as much as 400 ppm. The error built up over hours, then disappeared.
Both faults come from the flight hardware, and the sensors cannot be replaced before
launch. The acceptance test for the delivered software now includes both faults, along
with the dust storm from the original brief. The reference analyzer does not fly. The
flight software reads only the K30 and the SCD41.
The log from the test is attached. Use it to characterize each fault: when each event
began and ended, what each sensor reported during it, and what in the readings sets a
fault apart from normal sensor behavior. Then revise your CO2 sensor-trust logic and
show us evidence that it passes the acceptance test with these faults present.
Dr. Okafor
19.3.1. The Commissioning Log
Download the log, ghu2_commissioning_log.csv.
It holds one row per 60-second tick for six sols, with these columns.
The reference analyzer has an error of about 5 ppm. The K30 and SCD41 readings carry
normal measurement noise of about 20 ppm when they work.
Learning Objectives
- EB05:
Iterative Improvement - Present findings from iterative testing or optimization efforts.
- DV01:
Table and Plot Formatting - Prepare tables and plots for technical presentation with proper formatting. Include descriptive titles, axis labels with units, appropriately scaled axes, and visible legends.